Hms-En2mb-R Dimensions

Hms-En2mb-R Dimensions



Dimensions (L•W•H) 110 x 35 x 101mm or 4,33 x 1,38 x 3,98 Weight : 160 g, 0,35 lb : Operating temperature-25 to +70 °C or -13 to +158 °F : Storage temperature-40 to +85 °C or -40 to +185 °F : Power supply : 24 VDC +/- 20% : Current consumption: Typical 150 mA @ 24 V : Enclosure material: PC ABS, UL94 VO : Installation position : Vertical, HMS-EN2MB -R . Net Weight – 0.30kg . Additional Product Information … illustrations, drawings, dimensions , weights, measures, specifications, standards of performance or other descriptive matter of precontractual statement are approximate only and shall not form part of the contract. Business Customers:, Dimensions (L•W•H) 110 x 35 x 101mm or 4,33 x 1,38 x 3,98 Weight : 160 g, 0,35 lb: Operating temperature-25 to +70 °C or -13 to +158 °F : … HMS-EN2MB -R : Minimize costs when connecting Modbus-TCP networks/devices to ControlLogix® or CompactLogix® controllers with an EtherNet/IP interface.


HMS-EN2MB -R Linking Device INSTALLATION SHEET Further informa on and documents about this product can be found at the product pages on www.anybus.com. Supply voltage: The linking device requires a regulated 24 (20.4-28.8V) VDC power source. Field wiring terminal markings (wire type Cu only, 14-30AWG) “Use 105oC copper (Cu) wire only”, Dimensions (L•W•H) 110•35•101 mm, 4,33•1,38•3,98” Protection class IP20, NEMA rating 1 Enclosure material PC ABS, UL 94 VO Installation position Vertical Mounting DIN rail (35•7,5/15) or Wall Mount EN 50022 Certifications UL Yes Hazardous Locations Pending ATEX Pending CE Yes ODVA Yes Electrical Characteristics Power 24 VDC +/- 10 %, Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00 Weight: 400g or 0,880 lbs: Operating temperature-25 to +65 °C or -13 to +149 °F : Storage temperature-40 to +85 °C or -40 to +185 °F : Power supply: 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector : Current consumption : max. 400mA (Typical 200mA) Enclosure material, HMS-EN2MB -R Management…..47 Backup and Restore … Please note that the size of the I/O data that can be read from and written to the module is defined when configuring the linking device using the configuration pages.


Please note that the size of the I/O data that can be read from and written to the module is defined when configuring the linking device using the configu-ration pages. 2.6 Control Word 16 bit control word sent to the linking device from the PLC or EtherNet/IP scanner.


Configuring a Master/Slave combination. In this scenario, the configuration of the X-gateway is made in TWO steps. Firstly the amount of I/O and parameter data as well as the mapping of the data between the two networks is defined by using the Anybus Configuration Manager.


Configuring a Master/Slave combination. In this scenario, the configuration of the X-gateway is made in TWO steps. Firstly the amount of I/O and parameter data as well as the mapping of the data between the two networks is defined by using the Anybus Configuration Manager.